Trilogy O2 Ventilator, Recertified, Japan


Product Overview

Trilogy O2 Ventilator, Recertified, Japan
Trilogy O2 - Trilogy O2 Ventilator,Japan-RECERT


Device Description

A portable, electrically-powered device intended to provide long-term alveolar support for patients who do not require complex critical care ventilation. It typically uses positive pressure to deliver gas to the lungs at normal breathing rates and tidal volumes through invasive ventilation (i.e., with an artificial airway); it may also be used non-invasively (e.g., with a mask). It includes a control system and alarms, and may include a built-in humidifier. Several methods of cycling and ventilation modes may be used. It may be line and/or internal/external battery-powered for use in the home or a healthcare facility (including ambulatory).


Environmental Conditions

  • Storage Environment Humidity - Percent (%) Relative Humidity
    • 95.00
    • 15.00
  • Storage Environment Temperature - Degrees Fahrenheit
    • 140.00
    • -4.00

  • Device Sizes

    No Data Available


    Device Sterilization

    Device Sterile: False

    Sterilization Prior To Use: False

    Sterilization Methods: No Data Available


    Product Codes

    Code: DQA

    Device Name: Oximeter

    Device Class: 2

    Physical State: N/A

    Definition: N/A

    Submission Type ID: 1

    Review Panel: AN

    Review Code: N/A

    Technical Method: N

    Gmp Exempt Flag: N/A

    Life Sustain Support Flag: N

    Unclassified Reason: N/A

    Implant Flag: N

    Target Area: N/A

    Regulation Number: 870.2700

    Third Party Flag: N

    Medical Specialty: CV


    Code: OUG

    Device Name: Medical Device Data System

    Device Class: 1

    Physical State: Software and Electronics

    Definition: A medical device data system (mdds) is a device that is intended to provide one or more of the following uses, without controlling or altering the functions or parameters of any connected medical devices: (i) the electronic transfer of medical device data; (ii) the electronic storage of medical device data; (iii) the electronic conversion of medical device data from one format to another format in accordance with a preset specification; or (iv) the electronic display of medical device data. (2) An MDDS may include software, electronic or electrical hardware such as a physical communications medium (including wireless hardware), modems, interfaces, and a communications protocol. This identification does not include devices intended to be used in connection with active patient monitoring.

    Submission Type ID: 4

    Review Panel: HO

    Review Code: N/A

    Technical Method: N

    Gmp Exempt Flag: Software algorithms to perform necessary medical communication functions

    Life Sustain Support Flag: N

    Unclassified Reason: N/A

    Implant Flag: N

    Target Area: Hospital Information Systems

    Regulation Number: 880.6310

    Third Party Flag: N

    Medical Specialty: HO


    Code: CBK

    Device Name: Ventilator, Continuous, Facility Use

    Device Class: 2

    Physical State: N/A

    Definition: N/A

    Submission Type ID: 1

    Review Panel: AN

    Review Code: N/A

    Technical Method: N

    Gmp Exempt Flag: N/A

    Life Sustain Support Flag: Y

    Unclassified Reason: N/A

    Implant Flag: N

    Target Area: N/A

    Regulation Number: 868.5895

    Third Party Flag: N

    Medical Specialty: AN


    Device Identifiers

    Device Id: 00606959033948

    Device Type: Primary

    DeviceId Issuing Agency: GS1

    Contains DI Number: N/A

    Package Quantity: N/A

    Package Discontinue Date: N/A

    Package Status: N/A

    Package Type: N/A


    GMDN® is a registered trademark of The GMDN Agency. All rights reserved. The information provided on this site includes data supplied by The GMDN Agency ("GMDN Content"), which is used under licence from The GMDN Agency. Any data/information suppliers who wish to extract GMDN Content from this site in order to use it as a basis for creating and supporting commercial services such as alternative categorisation, alternative GMDN Term assignment, mapping to other categorisations or ontologies, or for AI training purposes, must first obtain an appropriate licence from The GMDN Agency. No such activity is permitted without a licence. For more information on obtaining a licence, please contact The GMDN Agency (https://www.gmdnagency.org/contact-us/). None of the GMDN content constitutes any endorsement, advice, representation or warranty about any specific medical devices that may be described by such content; and no representation or warranty is made in relation to instructions for use, suitability for any application, treatment or condition, regulatory status, or any properties of a particular medical device.

    GMDN ®. © GMDN Agency 2005-.
    Educational Resources