Lyra Direct CDIFF Assay
Lyra - Direct C. difficile Assay
Device Description
A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of nucleic acid, including specific gene markers from Clostridium difficile bacteria in a clinical specimen and/or culture isolate, using a nucleic acid technique (NAT). Markers detected may include genes conferring antimicrobial resistance (e.g., gyrA gene), virulence (e.g., ribotype 027) and genes encoding toxin A and/or B.
Environmental Conditions
- 8.00
- 2.00
Device Sizes
No Data Available
Device Sterilization
Device Sterile: False
Sterilization Prior To Use: False
Sterilization Methods: No Data Available
Product Codes
Code: OZN
Device Name: C. Difficile Toxin Gene Amplification Assay
Device Class: 2
Physical State: Not applicable
Definition: Amplification assay for the detection of c. Difficile toxin genes from stool specimens of symptomatic patients.
Submission Type ID: 1
Review Panel: MI
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: Uses amplification technology to detect toxin genes of C. difficile
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: Not applicable
Regulation Number: 866.3130
Third Party Flag: N
Medical Specialty: MI
Code: OOI
Device Name: Real Time Nucleic Acid Amplification System
Device Class: 2
Physical State: Should not include microarray or electrophoresis detection methods or instruments.
Definition: The system is a clinical multiplex instrument intended to measure and sort multiple signals generated my multiple probes, intercalating dyes, or other ligands in an assay from a clinical sample. Signals may be generated by fluorescence or other phenomena and may be measured using filters on a photodiode or other detector. It may integrate sample and/or reagent handling, amplification, dedicated instrument control, data acquisition software, raw data storage mechanisms and other essential hardware components along with the signal reader unit. The system is used with specific assays to comprise an assay test system.
Submission Type ID: 4
Review Panel: CH
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: A real-time thermocycler is intended to identify and/or quantify the presence of specific sequences of double stranded DNA, amplified from a biological source and labeled with fluorescently labeled probes or through the use of intercalating dyes and detect using a high-power light-emitting diode (LED). Fluorescence emission is detected through the use of filters on a photodiode. The emission filters are optimized for use with specific fluorescent dyes.
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 862.2570