SERTER MMT-7512N 1CLK GENERIC 2L


Product Overview

SERTER MMT
One-press Serter - MMT-7512N


Device Description

A device designed to be used by a layperson (this usually being the recipient of the injection) to reset the loaded position of an injector in a safe and controlled manner. It will typically be designed like a small box or container and have a hinged lid. The injector is placed inside this device and when the lid is closed an internal mechanism resets the injector to its firing position. The injector is removed from this device, the medication is inserted (typically a prefilled syringe or cartridge) and it is ready for use by the user. This is a reusable device.


Environmental Conditions

  • Storage Environment Humidity - Percent (%) Relative Humidity
    • 85.00
    • 15.00
  • Storage Environment Temperature - Degrees Celsius
    • 55.00
    • -20.00

  • Device Sizes

    No Data Available


    Device Sterilization

    Device Sterile: False

    Sterilization Prior To Use: False

    Sterilization Methods: No Data Available


    Product Codes

    Code: OZP

    Device Name: Automated Insulin Dosing Device System, Single Hormonal Control

    Device Class: 3

    Physical State: May include: Continuous glucose monitoring system, sensor, self monitoring blood glucose device, infusion pump, data management software

    Definition: An insulin-only automated insulin dosing system that achieves a target glucose level by automatically increasing or reducing insulin infusion from an insulin pump. Insulin adjustments are based upon specified thresholds of measured glucose levels.

    Submission Type ID: 2

    Review Panel: CH

    Review Code: N/A

    Technical Method: N

    Gmp Exempt Flag: Uses a glucose monitoring system to measure glucose levels and increases or reduces insulin infusion from an insulin pump

    Life Sustain Support Flag: N

    Unclassified Reason: N/A

    Implant Flag: N

    Target Area: Not meant to act on a specific part of the body but works with other devices - Continuous glucose monitoring system, sensor, self monitoring blood glucose device, data management software

    Regulation Number: N/A

    Third Party Flag: N

    Medical Specialty: N/A


    Device Identifiers

    Device Id: 00643169980525

    Device Type: Primary

    DeviceId Issuing Agency: GS1

    Contains DI Number: N/A

    Package Quantity: N/A

    Package Discontinue Date: N/A

    Package Status: N/A

    Package Type: N/A


    GMDN ®. © GMDN Agency 2005-2024.
    Educational Resources
    Videos