SPLITTER 5019 M
NA - 5019
Device Description
An implantable device used to provide a functional and modified connection between existing pacing leads (e.g., IS-1 leads) and an implantable pacing/defibrillation device (e.g., pacemaker, defibrillator). It typically consists of a small connector block to enable attachment to the pacing leads (i.e., when they do not meet connection design) and extension leads to increase the reach of the pacing leads. During implantation the surgeon uses a tool to tighten the connections (e.g., a Hex wrench), and a medical adhesive to seal the connections from body fluid contamination. This device facilitates the implantation of the pacing device and/or is useful if two leads need to be implanted.
Environmental Conditions
- 86.00
- 59.00
Device Sizes
No Data Available
Device Sterilization
Device Sterile: True
Sterilization Prior To Use: False
Sterilization Methods: No Data Available
Product Codes
Code: LWS
Device Name: Implantable Cardioverter Defibrillator (Non-Crt)
Device Class: 3
Physical State: These devices treat tachycardia (fast heartbeats) with RV defibrillation therapy as necessary.
Definition: These devices treat tachycardia (fast heartbeats) with RV defibrillation therapy as necessary.
Submission Type ID: 2
Review Panel: CV
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: These devices treat tachycardia (fast heartbeats) with RV defibrillation therapy as necessary.
Life Sustain Support Flag: Y
Unclassified Reason: N/A
Implant Flag: Y
Target Area: These devices treat tachycardia (fast heartbeats) with RV defibrillation therapy as necessary.
Regulation Number: N/A
Third Party Flag: N
Medical Specialty: N/A
Code: NVY
Device Name: Permanent Defibrillator Electrodes
Device Class: 3
Physical State: The device is a flexible, insulated electrical conductor with one end designed to make a secure connection to an ICD or CRT-D and the other end located in a position which directs defibrillation energy to the heart
Definition: Permanent defibrillator electrodes are used with compatible implantable cardioverter defibrillators (ICD) and cardiac rhythm therapy-defibrillators (CRT-D) to sense the cardiac rhythm and to deliver high energy therapy to the heart when tachycardia is detected. Some transvenous models can also be used for pacing the right ventricle.
Submission Type ID: 2
Review Panel: CV
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: Used as part of an implantable defibrillation system.
Life Sustain Support Flag: Y
Unclassified Reason: N/A
Implant Flag: Y
Target Area: Makes contact with the heart (endocardial or myocardial tissue) or is located in a proximity and orientation that creates a vector for defibrillation energy to the heart.
Regulation Number: N/A
Third Party Flag: N
Medical Specialty: N/A
Device IdentifiersDevice Id: 00763000571528
Device Type: Primary
DeviceId Issuing Agency: GS1
Contains DI Number: N/A
Package Quantity: N/A
Package Discontinue Date: N/A
Package Status: N/A
Package Type: N/A