The LIAISON PLEX® Respiratory Flex (RSP Flex) Assay is a multiplexed qualitative test for the simultaneous in vitro detection and identification of multiple bacterial and viral nucleic acids in nasopharyngeal swabs (NPS) obtained from individuals with clinical signs and symptoms of respiratory tract infection, including SARS
LIAISON PLEX® Respiratory Flex Assay Kit - 20-005-322
Device Description
A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of nucleic acid from multiple types of microorganisms (bacteria, fungi and/or viruses) associated with respiratory disease in a clinical specimen, using a nucleic acid technique (NAT). Organisms detected may include (but are not limited to) Streptococcus pneumoniae, influenza A, respiratory syncytial viruses A and B, rhinovirus, Haemophilus influenzae, Mycoplasma pneumoniae, Staphylococcus aureus, and/or enterovirus.
Environmental Conditions
- 30.00
- 15.00
Device Sizes
No Data Available
Device Sterilization
Device Sterile: False
Sterilization Prior To Use: False
Sterilization Methods: No Data Available
Product Codes
Code: QOF
Device Name: Multi-Target Respiratory Specimen Nucleic Acid Test Including Sars-Cov-2 And Other Microbial Agents
Device Class: 2
Physical State: A closed system disposable pouch that contains all necessary reagents for sample preparation, reverse transcription, polymerase chain reaction (PCR), and detection from multiple respiratory pathogens from a single nasopharyngeal swab specimen. The reagent pouch is hydrated with sample buffer and specimen to activate and is placed into an automated instrument to perform the sample preparation, PCR reaction, and detection for result generation.
Definition: A device to detect and identify nucleic acid targets in respiratory specimens from microbial agents that cause the SARS-CoV-2 respiratory infection and other microbial agents when in a multi-target test is an in vitro diagnostic device intended for the detection and identification of SARS-CoV-2 and other microbial agents when in a multi-target test in human clinical respiratory specimens from patients suspected of respiratory infection who are at risk for exposure or who may have been exposed to these agents. The device is intended to aid in the diagnosis of respiratory infection in conjunction with other clinical, epidemiologic, and laboratory data or other risk factors.
Submission Type ID: 1
Review Panel: MI
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: A nucleic acid amplification test (NAAT). PCR-based.
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: Nasopharyngeal (i.e., upper respiratory) swab specimen.
Regulation Number: 866.3981
Third Party Flag: N
Medical Specialty: MI
Device IdentifiersDevice Id: 00840487101940
Device Type: Primary
DeviceId Issuing Agency: GS1
Contains DI Number: N/A
Package Quantity: N/A
Package Discontinue Date: N/A
Package Status: N/A
Package Type: N/A