Bone Screw, Acetabular, 6.5mm x 25mm
Kyocera Medical Technologies, Inc. - A 450
Device Description
An implantable component of a two-piece acetabulum prosthesis that forms the outer portion of the prosthesis, fixed to the pelvis to provide a base for the inner portion (acetabular liner). It is made of metal, and is fixed with bone cement and/or fixation devices.
Environmental Conditions
No Data Available
Device Sizes
No Data Available
Device Sterilization
Device Sterile: True
Sterilization Prior To Use: False
Sterilization Methods: No Data Available
Product Codes
Code: LPH
Device Name: Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: OR
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: Y
Target Area: N/A
Regulation Number: 888.3358
Third Party Flag: N
Medical Specialty: OR
Code: LZO
Device Name: Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Device Class: 2
Physical State: N/A
Definition: N/A
Submission Type ID: 1
Review Panel: OR
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: Y
Target Area: N/A
Regulation Number: 888.3353
Third Party Flag: N
Medical Specialty: OR
Code: OQG
Device Name: Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented
Device Class: 2
Physical State: May include: Acetabular Shell Acetabular Liner Femoral Head Femoral Stem Femoral Neck Instrumentation
Definition: 1. Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis. 2. Rheumatoid arthritis. 3. Correction of functional deformity. 4. Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable by other techniques. 5. Revision procedures where other treatment or devices have failed. Cemented and uncemented use.
Submission Type ID: 1
Review Panel: OR
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: This device is intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene containing an additive such as a-tocopherol articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The stem/shell are coated with a porous coating to achieve cementless biological fixation.
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: Y
Target Area: Hip
Regulation Number: 888.3358
Third Party Flag: N
Medical Specialty: OR
Code: OQI
Device Name: Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
Device Class: 2
Physical State: May include: Acetabular Shell Acetabular Liner Femoral Head Femoral Stem Femoral Neck Instrumentation
Definition: 1. Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis. 2. Rheumatoid arthritis. 3. Correction of functional deformity. 4. Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable by other techniques. 5. Revision procedures where other treatment or devices have failed. Cemented and uncemented use.
Submission Type ID: 1
Review Panel: OR
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: A hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis is a device intended to be implanted to replace a hip joint. The two-part femoral component consists of a femoral stem made of alloys to be fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The proximal end of the femoral stem is tapered with a surface that ensures positive locking with the spherical ceramic (aluminium oxide, A1203) head of the femoral component. The acetabular component is made of ultra-high molecular weight polyethylene containing an additive such as a-tocopherol, and used with or without bone cement.
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: Y
Target Area: hip
Regulation Number: 888.3353
Third Party Flag: N
Medical Specialty: OR
Device IdentifiersDevice Id: 00841523106110
Device Type: Primary
DeviceId Issuing Agency: GS1
Contains DI Number: N/A
Package Quantity: N/A
Package Discontinue Date: N/A
Package Status: N/A
Package Type: N/A