Product Overview

NA - Ear tips for earphone, 8001233


Device Description

A mains electricity (AC-powered) device that applies sound stimuli (e.g., pure tones, speech) to a patient's acoustic system. It is typically used as a component of several types of devices such as audiometers, auditory evoked-potential recording systems, and auditory function screening devices.


Environmental Conditions

No Data Available


Device Sizes

No Data Available


Device Sterilization

Device Sterile: False

Sterilization Prior To Use: False

Sterilization Methods: No Data Available


Product Codes

Code: GWJ

Device Name: Stimulator, Auditory, Evoked Response

Device Class: 2

Physical State: N/A

Definition: N/A

Submission Type ID: 1

Review Panel: NE

Review Code: N/A

Technical Method: N

Gmp Exempt Flag: N/A

Life Sustain Support Flag: N

Unclassified Reason: N/A

Implant Flag: N

Target Area: N/A

Regulation Number: 882.1900

Third Party Flag: Y

Medical Specialty: NE


Code: ORT

Device Name: Burst Suppression Detection Software For Electroencephalograph

Device Class: 2

Physical State: Electroencephalograph analysis software. Does NOT include electrodes, electroencephalograph hardware, basic electroencephalograph software (e.g. used to display, store, archive, or manually annotate data), automatic event (i.e., seizure) detection software or automatic event-detection software used as an intermediary step in source-localization analysis.

Definition: Automatically mark or identify electroencephalograph waveforms for rhythmic patterns of burst suppression in order to aid in identification of such events and help in the review and annotation of prolonged EEG traces; software can also quantify simple characteristics of the burst suppression such as inter-burst interval or count; all output subject to verification by qualified user.

Submission Type ID: 1

Review Panel: NE

Review Code: N/A

Technical Method: N

Gmp Exempt Flag: Uses simple, transparent software algorithms to analyze any size montage (full or reduced) for burst suppression patterns and automatically identify areas of interest or quantify pattern characteristics.

Life Sustain Support Flag: N

Unclassified Reason: N/A

Implant Flag: N

Target Area: Brain

Regulation Number: 882.1400

Third Party Flag: N

Medical Specialty: NE


Code: OLT

Device Name: Non-Normalizing Quantitative Electroencephalograph Software

Device Class: 2

Physical State: Electroencephalograph analysis software. Does NOT include electrodes, amplitude-integrated electroencephalograph, automatic event-detection software, software that compares data to a database (normal or otherwise) or electroencephalograph software that outputs an index, classification, diagnosis, or any clinical interpretation of the data.

Definition: Analyze electroencephalograph data using conventional methodology to output and display standard electroencephalograph parameters for interpretation by a qualified user.

Submission Type ID: 1

Review Panel: NE

Review Code: N/A

Technical Method: N

Gmp Exempt Flag: Uses software algorithms as a tool to analyze electroencephalograph (from user-specified electrode number and locations) and automatically calculate conventional electroencephalograph parameters. (e.g. spectral edge frequency, total power, percent alpha, asymmetry).

Life Sustain Support Flag: N

Unclassified Reason: N/A

Implant Flag: N

Target Area: Brain

Regulation Number: 882.1400

Third Party Flag: Y

Medical Specialty: NE


Code: MHX

Device Name: Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)

Device Class: 2

Physical State: N/A

Definition: N/A

Submission Type ID: 1

Review Panel: CV

Review Code: N/A

Technical Method: N

Gmp Exempt Flag: N/A

Life Sustain Support Flag: N

Unclassified Reason: N/A

Implant Flag: N

Target Area: N/A

Regulation Number: 870.1025

Third Party Flag: N

Medical Specialty: CV


Code: OMC

Device Name: Reduced- Montage Standard Electroencephalograph

Device Class: 2

Physical State: May include standard EEG recording hardware (e.g. headbox, cables, CPU, monitor and basic software (needed to display, store and archive EEG and allow user-only annotation and marking); does NOT include electrodes, more complex software used to analyze EEG or automatically detect events, EEG used for PSG or sleep studies, or EEG with > 16 electrodes or more electrodes.

Definition: Acquire, display, store, and archive electroencephalographic signals from the brain using a user-specified and/or sponsor-specified locations with a reduced array (i.e. less than < 16) of electrodes

Submission Type ID: 1

Review Panel: NE

Review Code: N/A

Technical Method: N

Gmp Exempt Flag: Uses electrodes (less than < 16) placed on the scalp or within the brain, via user-specified and/or sponsor-specified locations, to record and display electrical activity of the brain

Life Sustain Support Flag: N

Unclassified Reason: N/A

Implant Flag: N

Target Area: Brain

Regulation Number: 882.1400

Third Party Flag: Y

Medical Specialty: NE


Code: MLD

Device Name: Monitor, St Segment With Alarm

Device Class: 2

Physical State: N/A

Definition: N/A

Submission Type ID: 1

Review Panel: CV

Review Code: N/A

Technical Method: N

Gmp Exempt Flag: N/A

Life Sustain Support Flag: N

Unclassified Reason: N/A

Implant Flag: N

Target Area: N/A

Regulation Number: 870.1025

Third Party Flag: N

Medical Specialty: CV


Device Identifiers

Device Id: 00840682103473

Device Type: Primary

DeviceId Issuing Agency: GS1

Contains DI Number: N/A

Package Quantity: N/A

Package Discontinue Date: N/A

Package Status: N/A

Package Type: N/A


GMDN ®. © GMDN Agency 2005-2024.