Vitamin D-direct w/ cal 1 x 100 tests


Product Overview

Vitamin D
CAROLINA LIQUID CHEMISTRIES CORP.® CLC720 Vitamin D CONTROL SET - ST500


Device Description

A material which is used to establish known points of reference for an assay intended to be used for the qualitative and/or quantitative detection of multiple forms of 25-hydroxy vitamin D in a clinical specimen.


Environmental Conditions

  • Special Storage Condition, Specify
    • Reagents, calibrators, diluent and control are stable when stored at 2 to 8°C until the expiration date on the label. After use, the solutions should be kept capped in its reagent bottle.
  • Storage Environment Temperature - Degrees Celsius
    • 8.00
    • 2.00

  • Device Sizes

  • Total Volume: 3 Milliliter
  • Kit contains 1 R1, 1 R2, 1 R3, 1 R4 (diluent), 1 each calibrators, C1, C2, C3, C4,& C5 and 1 package insert.
  • Total Volume: 7.5 Milliliter
  • Total Volume: 17 Milliliter
  • Total Volume: 13 Milliliter
    • Total Volume: 3 Milliliter
    • Kit contains 1 R1, 1 R2, 1 R3, 1 R4 (diluent), 1 each calibrators, C1, C2, C3, C4,& C5 and 1 package insert.
    • Total Volume: 7.5 Milliliter
    • Total Volume: 17 Milliliter
    • Total Volume: 13 Milliliter


    Device Sterilization

    Device Sterile: False

    Sterilization Prior To Use: False

    Sterilization Methods: No Data Available


    Product Codes

    Code: MRG

    Device Name: System, Test, Vitamin D

    Device Class: 2

    Physical State: N/A

    Definition: N/A

    Submission Type ID: 1

    Review Panel: CH

    Review Code: N/A

    Technical Method: N

    Gmp Exempt Flag: N/A

    Life Sustain Support Flag: N

    Unclassified Reason: N/A

    Implant Flag: N

    Target Area: N/A

    Regulation Number: 862.1825

    Third Party Flag: Y

    Medical Specialty: CH


    Code: JJX

    Device Name: Single (Specified) Analyte Controls (Assayed And Unassayed)

    Device Class: 1

    Physical State: N/A

    Definition: N/A

    Submission Type ID: 4

    Review Panel: CH

    Review Code: N/A

    Technical Method: N

    Gmp Exempt Flag: N/A

    Life Sustain Support Flag: N

    Unclassified Reason: N/A

    Implant Flag: N

    Target Area: N/A

    Regulation Number: 862.1660

    Third Party Flag: N

    Medical Specialty: CH


    Device Identifiers

    Device Id: 00817302020175

    Device Type: Primary

    DeviceId Issuing Agency: GS1

    Contains DI Number: N/A

    Package Quantity: N/A

    Package Discontinue Date: N/A

    Package Status: N/A

    Package Type: N/A


    GMDN ®. © GMDN Agency 2005-2024.