Optical Adhesive Cover
m2000 - 4J71-75
Device Description
A thin adhesive film intended to be used during in vitro diagnostic assays typically to seal the top of a microplate to prevent sample carryover and/or evaporation, and/or to fix test strips to a surface/chart to facilitate analysis. It is typically made of aluminium foil or plastic. This is a single-use device.
Environmental Conditions
No Data Available
Device Sizes
No Data Available
Device Sterilization
Device Sterile: False
Sterilization Prior To Use: False
Sterilization Methods: No Data Available
Product Codes
Code: OOI
Device Name: Real Time Nucleic Acid Amplification System
Device Class: 2
Physical State: Should not include microarray or electrophoresis detection methods or instruments.
Definition: The system is a clinical multiplex instrument intended to measure and sort multiple signals generated my multiple probes, intercalating dyes, or other ligands in an assay from a clinical sample. Signals may be generated by fluorescence or other phenomena and may be measured using filters on a photodiode or other detector. It may integrate sample and/or reagent handling, amplification, dedicated instrument control, data acquisition software, raw data storage mechanisms and other essential hardware components along with the signal reader unit. The system is used with specific assays to comprise an assay test system.
Submission Type ID: 4
Review Panel: CH
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: A real-time thermocycler is intended to identify and/or quantify the presence of specific sequences of double stranded DNA, amplified from a biological source and labeled with fluorescently labeled probes or through the use of intercalating dyes and detect using a high-power light-emitting diode (LED). Fluorescence emission is detected through the use of filters on a photodiode. The emission filters are optimized for use with specific fluorescent dyes.
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 862.2570
Third Party Flag: N
Medical Specialty: CH
Code: JJH
Device Name: Clinical Sample Concentrator
Device Class: 1
Physical State: N/A
Definition: N/A
Submission Type ID: 4
Review Panel: CH
Review Code: N/A
Technical Method: N
Gmp Exempt Flag: N/A
Life Sustain Support Flag: N
Unclassified Reason: N/A
Implant Flag: N
Target Area: N/A
Regulation Number: 862.2310
Third Party Flag: N
Medical Specialty: CH
Device IdentifiersDevice Id: 00884999006539
Device Type: Primary
DeviceId Issuing Agency: GS1
Contains DI Number: N/A
Package Quantity: N/A
Package Discontinue Date: N/A
Package Status: N/A
Package Type: N/A